Quick Details
- Warranty:12 months
- Monitor:19" LCD
- Display mode:B, BB, 4B, B+M , M, PWD, PwrD, CD, CWD, DirPwr, B+C+D
- Certificate:CE ISO
- Dynamic range:30dB-75dB
- Power Source:Electricity
- Image gray scales:256 scales
- Instrument classification:Class II
- Processing Time:within 3-5 working days
- Port:Shenzhen
- Supply Ability: 100 Units Per Month
- Brand Name:Weikang
Technical specifications and feature
Technical Parameters
Monitor
19” high-resolution LCD color monitor
Gray scale
256
Scanning lines
≥256
Dynamic Range
30dB-75dB
Maximum frame rate
≥65/s
Pseudo-color display
11
Note
body mark and character note, body mark: ≥100
Cine loop
≥100 frame
Image memory
≥160G, format BMP/JPG/DCM/TIF
TGC
≥8
Partial enlarged
≥ 4 times
Image mode
B, BB, 4B,
B+M , M, PWD, PwrD, CD, CWD, DirPwr, B+C+D
Image processing
8 frame-related, 6 related to six-speed lines
Image flip
up and down , left and right , image rotation ( 2B, 4B mode rotated 90 ° ) , black and white DICOM3.0 interface with network remote
assistance software
Sampling frame size, position and color
support B / color consistent width adjustable
Pulse repetition frequency
0.5-2khz , 6 adjustable
Gain
20dB-48dB , grading adjustable
Wall filter
40-500 adjustable
Noise Reduction
32 adjustable
Sample volume
0.5-10mm adjustable range 20
Scan speed
8 adjustable
Support synchronous updates automatically trace and spectral inversion
Baseline position, spectrum volume and correction angle
adjustable
Blood flow measurement velocity
a) Maximum blood flow velocity measurement : pulse doppler > 2m/s
b) Lowest measured blood flow velocity : <2mm /s (non-noise signals)
Port and holder
4 activated probe ports and holders, 1 Gel heater holder
Input / Output Interface
USB2.0 , LAN , VGA , RS232 , Video, DICOM3.0, foot switch, XGA, DVD
burner
Machine dimension
920*550*1450mm
Measurement
Mode B (2D) measurement
a) General measurement: distance, perimeter, area, volume, distance narrower radio, area stenosis ratio.
b) Gynecological measurement: uterine size and volume, cervix size and volume, right/left ovary size and volume,
endometrial thickness, right/left follicle volume.
M mode measurements: distance, heart rate.
Doppler measurements: General measurement: systolic and end-diastolic velocity, peak flow, time, blood flow, pulse
index and heart rate.
Standard
Configuration
Scanner Body: 1pc3.5Mhz Convex Probe: 1pc
Charger with a Set of Wires: 1setBottle of USG gel: 1pcUser Manual: 1pc
USB disk: 1pc
Optional
Micro-convex probe
Phased array probe
Trans-virginal probe
Linear probe
4D Volume probe
Printer
Guided probe holder