JTY-GD-2412/24E Point Type Photo-electric Smoke Detector

FOB Price: USD 70.00 - 65.00
|
40 Pieces (Min. Order)
  • Supplying Ability100 Pieces Per Week
  • Supplying TypeOem service
  • Model NumberJTY-GD-2412/24E
  • Preferred Payment Method:T/T, Western Union, Money Gram, PayPal

timbermate company limited

Thailand

Port: Leam Chabang Port

Quick Details

  • Processing Time:15 - 25 days
  • Port:Leam Chabang Port
  • Supply Ability: 100 Pieces Per Week
  • Brand Name:Chuangdi
Supply Ability Supply Ability: 100 Piece/Pieces per Week Packaging & Delivery Packaging Details Packed with carton or wood boxes Port Leam Chabang Port Picture Example: Lead Time : Quantity(Pieces) 1 - 10 11 - 50 >50 Est. Time(days) 15 25 To be negotiated JTY-GD-2412/24E point type photo-electric smoke detector Product Description I. Overview of JTY-GD-2412/24E Point Photoelectric Smoke Smoke Detector   JTY-GD-2412/24E Photoelectric Smoke Detector is a dual-source dual-chamber photo-electric smoke detector using modern modern technology. It can work under the supply voltage of 12V system, especially suitable for security system and detector. After the alarm, a built-in relay can be activated to provide two pairs of normally open and normally closed contacts for interlocking external devices.   The JTY-GD-2412/24E Photoelectric Smoke Detector is designed to provide protection for open areas and must be used with compatible four-wire controllers. The detector's health and sensitivity can be tested in the field.   As a self-locking detector, when the alarm is locked, it must be reset by momentary interruption of the power supply. The JTY-GD-2412/24E photo-electricity smoke detector has a light-emitting diode as the display of the detector. If the detector is energized and in normal monitoring, the LED will flash every 10 seconds. In the alarm state, the LED will lock steady until the detector is reset.   The JTY-GD-2412/24E Photoelectric Smoke Detector contains a pair of normally open contacts (Type A) for connection to the alarm control circuit and a set of normally open/normally closed auxiliary contacts (Type C). Monitoring of the detector power supply is accomplished by installing a power monitoring terminal relay at the end of the detector power circuit. When current is applied to and through the detector, the terminal power monitoring module is powered up and its relay contacts are closed to cause the controller's alarm loop to form a closed series circuit. Once the power is turned off or the detector circuit is disconnected, the terminal module will lose power and the relay contacts will disengage and trigger a fault signal to the controller.   2, JTY-GD-2412/24E point type photo-electricity smoke fire detector technical parameters   14cm (5.5 inches) in diameter   Height 8.1cm (3.19 inches)   Weight 310g (0.7 lbs)   Operating temperature range -10 ° C to 50 ° C (14 ° to 122 ° F)   Operating humidity range 10% to 95% RH relative humidity   Alarm reset instantaneous power off   Maximum wind speed 15M / S (3000 feet / Min)   Relay contact parameters   Resistive or inductive (60% power factor) load   Type A: 2.0A@30VAC/DC   Type C: 0.6A@110VDC, 2.0A@30VDC   1.0A@125VDC, 2.0A@30VDC   Electrical parameters: 12VDC power supply 24VDC power supply   System voltage: 12DC (maximum 4V fluctuation) 24DC (maximum 4V fluctuation)   Supply voltage: 11.3VDC minimum, 17.0VDC maximum 20VDC minimum, 29VDC maximum   Reset voltage: 0.73VDC minimum 0.8VDC minimum   Quiescent current: 120μA maximum 120μA maximum   Alarm current: 35.0mA minimum 77.0 maximum 21.3mA minimum, 40.6mA maximum   Reset time: 0.3 seconds 0.3 seconds   Power-on time: 34 seconds 34 seconds FOR MORE DETAILS PLEASE CALL OR EMAIL US CONTACT NUMBER.+66636524055 WHATSAPP. +66636524055 EMAIL.. mw2945576@gmail.com