Electric Hydrostatic Test Bench

FOB Price: Get Latest Price
|
1 Pieces (Min. Order)
  • Supplying Ability1000 Pieces Per Year
  • Supplying TypeOem service
  • Model NumberHPU-A-S**
  • Preferred Payment Method:T/T, L/C

Quick Details

  • Processing Time:30days
  • Port:SHEKOU
  • Supply Ability: 1000 Pieces Per Year
  • Brand Name:IVS
1. MODEL ordering:IVS -  HPU -  A -  S4005 – S                           1      2     3      4     5 Tabe-1: Manufacture:IVS Tabe-2: Product: HPU-Hydraulic Power Unit Tabe-3: Operation code: M-manual / A-auto Tabe-4: Model Data: S-single acting; D-double acting;        S/D4***-series, S/D5***-series, S/D7***-series (See Chart-1 ) Tabe-5:S/P/C       S: Static pressure or burst        1. Static pressure: Conduct static pressure holding testing and record the leak volume (pressure         differential) 2. Burst function: Conduct burst testing within the max. Output pressure and record the peak pressure     3. Or combine the static pressure testing and burst testing       P: Pulse, and it is only for the single acting pumps, frequency ≤0.5HZ,and the pulses deformation                 will be less than the pump volume when the pulse pressure within the static pressure       C: Auto calibration for pressure gauges. Chart-1 4***series  Pump Ratio Volume Static pressure Kgf/cm2 Single acting Double acting Min. Max. S- Volume per Stroke /ml Max. Volume   ml/min D- Volume per Stroke /ml Max. Volume ml/min 005 42 4200 84 8400 2.5 35 010 22 2200 44 4400 5 70 020 12 1200 24 2400 10 140 030 7.5 750 15 1500 15 210 040 6 600 12 1200 20 280 060 4 400 8 800 30 420 110 2 200 4 400 55 770 155 1.5 150 3 300 77.5 1085 240 1 100 2 200 120 1680 300 0.8 80 1.6 160 150 2100 5***series Pump Ratio Volume Static pressure Kgf/ cm2 Pump Ratio Single acting Double acting Min. Max. Volume per Stroke       /ml Max. Volume    ml/min Volume per Stroke /ml Max. Volume    ml/min 005 90 9000 180 18000 2.5 35 010 42 4200 84 8400 5 70 012 36 3600 72 7200 6 84 020 22.5 2250 45 4500 10 140 025 16 1600 32 3200 12.5 175 030 14 1400 28 2800 15 210 035 12 1200 24 2400 17.5 245 055 7.5 750 15 1500 27.5 385 070 6 600 12 1200 35 490 085 5 500 10 1000 42.5 595 105 4 400 8 800 52.5 735 140 3 300 6 600 70 980 195 2 200 4 400 97.5 1365 280 1.5 150 3 300 140 1960 440 1 100 2 200 220 3080 555 0.75 75 1.5 150 277.5 3885 7***series Pump Ratio Volume Static pressure Kgf/ cm2 Single acting Double acting Min. Max. Volume per Stroke         /ml Max. Volume ml/min Volume per Stroke /ml Max. Volume   ml/min 005 290 29000 580 58000 2.5 35 010 146 14600 292 29200 5 70 020 66 6600 132 13200 10 140 025 55 5500 110 11000 12.5 175 035 40.5 4050 81 8100 17.5 245 055 24.5 2450 49 4900 27.5 385 095 15 1500 30 3000 47.5 665 145 10 1000 20 2000 72.5 1015 180 8 800 16 1600 90 1260 240 6 600 12 1200 120 1680 330 4 400 8 800 165 2310 460 3 300 6 600 230 3220 740 2 200 4 400 370 5180 NOTES:1. S-Single acting; D-Double acting  2. The output pressure and flow rate act as reference for order and their real valve will vary according to pressure and driven air Chart-1 2.    User facility on site: 1. Air supply 7-10bar, 2. Power supply for auto type :220V 50HZ 500W, 3. Fit indoor safe area; 4. Please consult for I.P protection and hazard area, 3.    Features: 1. Pressure control:≤1% F.S 2. Leak rate:≤1% of set point 3. Sampling frequency:0~1000 Hz 4. Stable Pressure:≤1% F.S 5. Inlet: Medium inlet 1/2”NPTF; Air inlet,1/2”NPTF 6. Outlet:<100MPa,3/8”NPTF ;> 100MPa, HF6 7. Relief port:3/8”NPTF 4.    Material: 1. Liquid contact: tube and fitting- SS; 2. Pump material can be optional in copper alloy and SS, 3. Cabinet: Carbon steel/SS 5.    Schematic:                               6.    Reference Profile: Size: L600mm*W500mm*H450mm Weight:Varys from models