Quick Details
- Processing Time:-
- Port:
- Supply Ability: -
- Brand Name:QOLTEC
PRODUCT DESCRIPTION
Qoltec emergency power system UPS offline is a modern and economical device, which provides emergency power to connected loads when the input power source or mains power fails. UPS protects
connected devices from power disruption, voltage spike and eliminates possible damage in case of mains power overvoltage. It also protects connected loads from overloads and short circuit.
Qoltec UPS offline meets everyone’s requirements, who are looking for a device, which protects connected loads from an instability of the mains frequency. Thanks to high quality and wide
operating range it is a perfect solution for people who want to have ensured the continuity of operation of computers and other peripheral devices in a home, enterprise, educational institutions
and government offices. UPS offline is also indispensable to power central heating pump.
* We look for distributors from European countries *
TECHNICAL DATA
USABLE POWER
720W
RATED CAPACITY
1200VA
POWER FACTOR
0.6
LOAD TYPE
Personal computer and other PC peripheral devices
AC VOLTAGE RANGE
140Vac ~ 290Vac / ±5Vac
AC FREQUENCY
40Hz ~ 70Hz / ±1Hz
OUTPUT RANGE (LINE)
220Vac - 230Vac / ±10%
OUTPUT FREQUENCY (LINE)
40Hz ~ 70Hz / ±1Hz
OUTPUT VOLTAGE (BATTERY)
220Vac - 230Vac / ±5%
OUTPUT FREQUENCY (BATTERY)
50Hz - 60Hz / ±1Hz
TRANSFER TIME
≤ 10ms
OUTPUT SOCKETS
1 x IEC
3 x SCHUKO
BACKUP TIME
> 6 min (half charge)
BUILT-IN BATTERY
2x12V / 9Ah
CHARGING TIME
8 hrs (to fully charged)
STORAGE TEMPERATURES
-15C to 45C
OPERATING TEMPERATURE
0C to 40C
RELATIVE HUMIDITY
0% - 90%
SAFETY
Surge protection
Overload protection
Short protection
High / low voltage protection
ADDITIONAL INFORMATION
Auto charging
Charging in UPS OFF Mode
Sound signal
LEDs
PACKAGE CONTENTS
UPS
Power cable (1xSchuko) 1.2m
User manual
Warranty card
NOISE
≤ 35dB ( 1 meter from front panel)
DIMENSIONS
341 x 122 x 195 mm
WEIGHT
10 kg
WARRANTY
24 months
EAN CODE
5901878539041
PROTECTIONS
Short circuit
Auto protection. Output shuts off and the buzzer beeps continuously.
Overload
110%≤ 120%, buzzer beeps. UPS switches off within 5 minutes; >120% buzzer beeps continuously, UPS immediately turns off
Battery protection
Auto protection. The UPS auto shutdown when the battery voltage is low or high.
CERTIFICATES
All of our products have tests reports required to comply with EMC, LVD, Eco and RoHs Standards, which means they are CE marked.
SHIPPING
We help to organise cheap shipping in whole Europe.
We encourage to visit our site: