Quick Details
- Processing Time:-
- Port:-
- Supply Ability: -
- Brand Name:-
SARS-CoV-2 Antigen Swab Test Kit 1 Tests/Kit CE for Nasal Swab Specificity
100%
Early Symptoms
New coronary pneumonia generally has no obvious precursors. In the early stage of the disease after
infection with the COVID-19, some patients may not have any obvious symptoms. Most other patients often have fever, dry cough, and fatigue as the main manifestations, but in addition, due to
individual differences , The patient may also have muscle pain, chest tightness, itchy throat, sore throat, nasal congestion, runny nose, diarrhea, abnormal taste and other symptoms. These
symptoms lack specificity and can be seen in many diseases, not unique to the new crown. Therefore, it is actually difficult for patients to identify whether they are infected with the COVID-19
by their own symptoms. When the above-mentioned symptoms appear, and you believe that you may have been exposed to the COVID-19 or infected people in the past, you should go to a medical
institution for relevant examinations as soon as possible to confirm the diagnosis.
Materials Provided
Component
Description
Specification
1 test/kit
Test cassette
Foil ouched test device containing one reactive strip.
1
Sterile swab
For sample collection and transfer.
1
Inside page
Instructions for use.
1
Extraction buffer
Dissolve the sample
1
The certificate of conformity
1
Packages with holes
Be used as tube stand (optional).
1
Detection Limit
The limit of detection (LOD) for the SARS-CoV-2 Antigen Rapid Test is 4 x 102 TCID50/mL.
Matrix
LOD Concentration TCID50/mL
Number of Positive/ Total
%Detected
A viral sample inactivated by gamma
irradiation
4 x 102TCID50/mL
20/20
100%
Interference
The following interfering substances have no impact on SARS-CoV-2 Antigen Rapid Test (Colloidal
Gold).
No.
Interfering Substance
Final Test Concentration
1
Mucin
0.54%
2
Menthol
1.4 mg/mL
3
Whole Blood
5%
4
Triamcinolone acetonide
1 ng/mL
5
Tobramycin
5 μg/mL
6
Levofloxacin
1.5 μg/mL
7
Mupirocin
12 mg/mL
8
Oxymetazoline
9%v/v
9
Nasal Spary
16%v/v
10
Dexamethasone
0.5 μg/mL
Hook Effect
No high dose hook effect was observed when tested with up to a concentration of 1.3 x 106 TCID50/mL of heat
inactivated SARS-CoV-2 virus.
Warnings And Important Information
1. The test is designed for external use outside human body only. Please do not ingest. Avoid skin and eye
contact with the buffer liquid.
2. Failure to follow the instructions may affect the test result. The final diagnosis should be confirmed
by a physician.
3. Keep it out of reach of children.
4. Persons with reduced vision or mobility should ask for assistance.
5. Do not use the test if test components are damaged.
6. Use only the materials supplied with this test. Do not reuse the test or test components.
7. The test should be performed immediately, latest one hour after opening the foil pouch (at 20-30°C,
humidity<60%).
Positive Test Result
If a colored line is visible in the test line region (T) and a colored line is visible in the control line
region (C), indicating positive test result. This means that SARS CoV-2 antigens are detectable in your nasal sample and indicates with high probability of COVID-19 infection.
Please stay home and call your doctor or local health department. Follow local self-isolation guidelines
and take a PCR confirmation test.
* Note: Line thickness is irrelevant; any reddish lines in the test line (T) should be interpreted as a positive test result. Positive test results must be confirmed by molecular diagnostics such
as PCR testing.
Negative test result
If only colored lines are visible in the area of the control line (C), but not at the test line (T), the
test result is negative. This suggests that the nasal samples were either absent or too little of the SARS-CoV-2 antigen and probably not infected with the SARS-CoV-2 virus.
Continue to follow applicable rules regarding contact with others and applicable protective measures. In
case of suspicion, repeat the test using new test kit, as SARS-CoV-2 virus cannot be accurately detected at all stages of infection. A negative result does not rule out infection with SARS CoV-2
and should be confirmed by PCR testing if suspected.
INVALID TEST RESULT
If no line is visible in the control line (C) or only one line is visible in the test line area (T),
indicating the test is not performed correctly and the result is invalid. It is important to follow the instructions for the test carefully. Please repeat the test with new sample and new test
set.
If test results remain invalid, please contact a physician or COVID-19 testing center.
Interpretation Of The Test Result
Check whether a line is visible at the control line (C). The color thickness of the control line (C) is
irrelevant. If it is not visible, the test was not performed correctly and a new test with a new test set must be performed.
Storage and disposal
Store at room temperature (2-30°C or 35.6-86 T).
Shelf life 12 months (from production date to expiration date).
Test cassettes must be stored in airtight foil pouches until use. Do not use after expiration date.
Waste from used tests should be disposed of according to local regulations.