Quick Details
- Processing Time:-
- Port:-
- Supply Ability: -
- Brand Name:-
PRODUCT DESCRIPTION
FD520 digital ultrasonic flaw detector , ultrasonic flaw detection equipment dust proof
Main features:
★ Automated calibration,Automated gain, 0-120dB gain
★ DAC,AVG,TCG,B scan,AWS
★ High-speed capture and very low noise
★ Solid metal housing,water / oil proof,dust proof
★ high contrast viewing of the waveform from bright
★ Powerful pc software and reports can be export to excel
Automated display precise flaw location(Depth d,level p,distance s,amplitude,sz dB,ф);
Automated switch three staff gauge ((Depth d,level p,distance s);
Automated calibration of transducer Zero-point, Angles, Front edge and material Velocity ;
Convenient to make and use DACTCG and AVG to evaluate the echo, the curve can be modified and compensated
6dB DAC functions;
500 independence setup, any criterion can be input freely, we can work in the scene without test block;
Big memory of 1000 A graph
Automated gain and gain scan;
Peak Hold and Peak Memory;
B scan;
AWS D1.1
Automated make video of test process and play; use upan,the length of video is unlimited.
Powerful pc software and reports can be export to excel;
Li battery, continue working time up to 12 hours;
The embeded software can be online updated;
Other assistant function
Display freeze;
Automated echo degree;
Angles and K-value;
Lock and unlock function of system parameters;
Electronic clock calendar ;
Two gates setting and alarm indication;
Gate and DAC alarm;
Title
Parameter
Title
Parameter
Measuring Range(mm)
0 ~ 10000
Measurement Mode
Single,Dual,Thru
Vertical Linearity Error
≤3%
Reject
0~80%
Horizontal Linearity Error
≤0.1%
Pulse Displacement(μs)
-20 ~ +3400
Sensitivity Leavings
≥62dB
Zero(μs)
0.0 ~ 99.99
Dynamic range
≥32dB
Port Type
BNC(Q9)
Resolving Power
≥36dB
Operating Temperature (℃)
-20~50
Frequency Range(MHz)
0.5 ~ 15
H×W×D(mm)
240×156×48
Gain(dB)
0 ~ 120
Weight(kg)
1.0(with battery)
Material Velocity(m/s)
1000 ~ 15000
Standard Delivery:
Main unit
2.5MHZ-ф20 straight probe
4MHZ-8x9mm, 60degree angle probe
4A/9Vpower adapter
Probe connection cable (BNC to BNC)
Probe connection cable (BNC to Lemo 00)
Instruction manual
Carrying case
RS232-USB converter
Additional Accessories:
Data managing software
Data managing cables
RS232
Straight probe
(5MHZ-ф20)
Straight probe
(2.5MHZ-ф20)
Straight probe
(2.25MHZ-ф20)
Straight probe
(1MHZ-ф20)
Angle probe (4MHZ-45degree, 8*9mm)
Angle probe (4MHZ-60degree, 8*9mm)
Angle probe (4MHZ-70degree, 8*9mm)
Angle probe (4MHZ-80degree, 8*9mm)
Angle probe (2MHZ-45degree, 8*9mm)
Angle probe (2MHZ-60degree, 8*9mm)
Angle probe (2MHZ-70degree, 8*9mm)
Angle probe (2MHZ-80degree, 8*9mm)
Probe T/R (5MHz-ф20mm, focus 15mm)
Probe T/R (2.5MHz-ф20mm, focus 15mm)
Connection cable to probe
(BNC-BNC)
Connection cable to probe (BNC-Lemo
00)
Connection cable to probe (BNC-Lemo
01)
Connection cable to probe (Lemo 00-Lemo
01)
Lithium ion
battery
Power adapter
(4A/9V)
Power
Cable
Leather case
Comparison sheet