SA2100 Power Quality Analyzer Portable Power Quality Analyzer Supplier

FOB Price: Get Latest Price
|
5 (Min. Order)
  • Supplying Ability30000 Sets Per Year
  • Supplying TypeOem service
  • Model Number-
  • Preferred Payment Method:T/T

Shijiazhuang Suin Instruments Co., Ltd

China

Port: Tianjin, Shanghai, Shenzhen

Quick Details

  • Processing Time:Peak season: average one month; Off season: average 15 workdays
  • Port:Tianjin, Shanghai, Shenzhen
  • Supply Ability: 30000 Sets Per Year
  • Brand Name:SUIN
SA2100 Power Quality Analyzer Portable        Power Quality Analyzer Supplier   Overview SA2100 Power Quality Analyzer is a handheld multi-functional device which is designed to measure and analyze single or three-phase power system. This portable class S device can provide safe, convenient and accurate measurements for troubleshooting power networks.   Application Electrical power, medical, transportation, telecommunication, other industrial areas   Design Features Basic voltage measurement accuracy of±0.5% 1-50th harmonic display Support dynamic measurement such as Inrush, Flicker and Transients. 10 kinds of language are available to select Powerful logger function   Specifiations Measurement Range Resolution Accuracy Voltage/Current/Frequency Vrms(AC+DC) 1~ 1000Vrms 0.1Vrms ±0.5% of nominal voltage Vpk 1 ~ 1400Vpk 0.1Vpk ±0.5% of nominal voltage V(Crest Factor) 1.0 ~>2.8 0.01 ±5% Arms (AC)  10mV/A 0 ~ 100A 0.1A ±0.5%±0.2A 1mV/A 1~1000A 0.1A ±0.5%±0.2A 50mV(65mV)/1000A 15~5000A 1A ±1%±2A A(Crest Factor) 1~10 0.01 ±5% Frequency 42.5 ~ 57.5Hz (50Hz nominal) 0.01Hz ±0.01Hz 51 ~ 69Hz (60Hz nominal) 0.01Hz ±0.01Hz 385~414Hz (400Hz nominal) 0.01Hz ±0.1Hz Dips & Swells Vrms1/2 0   ~ 200% of nominal voltage 0.1Vrms ±1% Arms1/2 1 ~ 3000A 1A ±1%±2A Duration hour-minute- second- microsecond                   0.5 cycle 1 cycle Harmonic(IEC61000-4-7) Harmonic Number 1 ~ 50 Harmonic Voltage %f 0.0 ~ 100.0% 0.10% ±0.1%±nx0.1% Harmonic Current %f 0.0 ~ 100.0% 0.10% ±0.1%±nx0.1% THD 0.0 ~ 100.0% 0.10% ±2.5% Phase -360° ~ 0° 1° ±nx1.5° Power and Energy Active Power/Apparent Power/Reactive Power 1.0 ~ 20.00MW 0.1kW ±1.5±10 digits KWh 0.00kWh ~ 200GWh 10Wh ±1.5±10 digits Power Factor 0 ~ 1 0.01 ±0.03 Flicker (IEC61000-4-15) Pst(1min),Pst,Plt,PF5 0.00 ~ 20.00 0.01 ±5% Unbalance Voltage 0.0 ~ 5.0% 0.10% ±0.5% Current 0.0 ~ 20.0% 0.10% ±1% Voltage Phase -360° ~ 0° 1° ±2digits Current Phase -360° ~ 0° 1° ±5digits Voltage Transient  Vpk ±6000Vpk 1V ±15% Vrms 10 ~ 1000Vrms 1V ±2.5% Min. Test Time 50us Inrush Current Arms 0~3000Arms 0.1 ±1%±5digits Inrush Duration 6s ~ 32min selectable 10ms ±20ms Logger Recording user-defined parameters for 4 phases at the same time Memory Data stored in Micro SD card, 8GB Duration Time 2 hrs to 1 year, depends on the recording items and time interval Interval 1s to 1 hrs Monitor Support EN50160 in default or user-defined standard   Channel(Voltage/Current) 4/4 Voltage Range 1-1000Vrms, 6000V transient voltage Current Range depends on supplied current clamp Micro SD card(bulid-in) 8GB Battery NI-MH, 3800Ah/>7h interface USB Host, LAN Screen 5.6' TFT LCD with resolution320*240(SA2100) Language 9-Chinese, English, French, German, Korean, Polish, Portuguese , Spanish, Turkish Dimension/Weight           262*173*66mm/1.6kg Wire Combinatios           1Ø+NEUTRAL,1Ø SPLIT PHASE,1Ø IT NO NEUTRAL,3Ø   WYE, 3Ø DELTA, 3Ø IT, 3Ø HIGH LEG, 3Ø OPEN LEG,  2-ELEMENT, 2 1/2-ELEMENT Electrical Safety IEC61010-1 ,Safety Degree: 600V CAT IV    1000V CAT III    

You May Be Intrested In