Quick Details
- Processing Time:10-30 days
- Port:Ningbo Port, China
- Supply Ability: 345000 Cartons Per Month
- Brand Name:leadhua
R134a
1 PRODUCT AND COMPANY IDENTIFICATION
Product Name: R134a
Chemical Formula: CF3CH2F
Chemical Name: 1,1,1,2-tetrafluoroethane (HFC - 134a)
Use: Refrigerant gas
2 COMPOSITION / INFORMATION ON INGREDIENTS
CAS NO. 811-97-2
Purity: 99.9%
1,1,1,2-tetrafluoroethane
Flash Point: Non-flammable
Ignition Temperature: n/a Non flammable
Upper explosive limit/upper flammability limit: n/a
Non flammable
Vapour pressure: 4.909 Bar (4909 hPa) at 21oC
Liquid Density: 1200 kg/m3 at 25oC
Vapour Density: 5.368 kg/m3 at 21oC
Water solubility: 1.5 g/l
Vapour Density (Air = 1) 3.5
3 Emergency Overview
Clear, colorless liquefied gas with faint ethereal (either like) odor.
WARNING!
Liquid And Gas Under Pressure, Overheating And Over Pressurizing May Cause Gas Release Or Violent Cylinder Bursting. May Decompose On
Contact With Flames Or Extremely Hot Metal Surfaces To Produce Toxic And Corrosive Products. Vapor Reduces Oxygen Available For Breathing And Is Heavier Than Air. Harmful If Inhaled And May Cause
Heart Irregularities, Unconsciousness Or Death. Liquid Contact With Eyes Or Skin May Cause Frostbite.
4 FIRST AID MEASURES
IF IN EYES, immediately flush with plenty of water. Get medical attention if irritation persists.
IF ON SKIN, Flush exposed skin with lukewarm water (not hot), or use other means to warm skin slowly. Get medical attention if frostbitten
by liquid or if irritation occurs.
IF SWALLOWED, Not applicable - product is a gas at ambient temperatures.
IF INHALED, remove to fresh air. If not breathing, give artificial respiration. If breathing is difficult, give oxygen. Get medical
attention. Do not give adrenaline, epinephrine or similar drugs following exposure to this product.
5 FIRE FIGHTING MEASURES
Fire and Explosive Properties
Auto-Ignition Temperature 743 C (1 bar)
Flash
Point NA -
GAS
Extinguishing Media
Use extinguishing media appropriate to surrounding fire conditions.
Fire Fighting Instructions
Stop the flow of gas if possible. Use water spray on person making shut-off. Fire fighters and others who may be exposed to products of
combustion should wear full fire fighting turn out gear (full Bunker Gear) and self-contained breathing apparatus (pressure demand NIOSH approved or equivalent). Fire fighting equipment should be
thoroughly decontaminated after use.
6 ACCIDENTAL RELEASE MEASURES
In Case of Spill or Leak
Use Halogen leak detector or other suitable means to locate leaks or check atmosphere. Keep up wind. Evacuate enclosed spaces and disperse
gas with floor-level forced-air ventilation. Exhaust vapors outdoors. Do not smoke or operate internal combustion engines. Remove flames and heating elements.
7 HANDLING AND STORAGE
Handling
Avoid breathing gas. Avoid contact with eyes, skin and clothing. Keep container closed. Use only with adequate ventilation. Do not enter
confined spaces unless adequately ventilated.
Storage
Do not apply direct flame to cylinder. Do not store cylinder in direct sun or expose it to heat above 120 F. Do not drop or refill this
cylinder. Keep away from heat, sparks and flames.
8 EXPOSURE CONTROLS / PERSONAL PROTECTION
Engineering Controls
Investigate engineering techniques to reduce exposures below airborne exposure limits. Provide ventilation if necessary to control
exposure levels below airborne exposure limits (see below). If practical, use local mechanical exhaust ventilation at sources of air contamination such as open process equipment.
Eye / Face Protection
Where there is potential for eye contact, wear chemical goggles and have eye flushing equipment available.
Skin Protection
Wear appropriate chemical resistant protective clothing and chemical resistant gloves to prevent skin contact. Consult glove manufacturer
to determine appropriate type glove material for given application. Rinse contaminated skin promptly. Wash contaminated clothing and clean protective equipment before reuse. Wash skin thoroughly
after handling.
9 STABILITY AND REACTIVITY
Stability
This material is chemically stable under specified conditions or storage, shipment and/or use. See
HANDLING AND STORAGE section of this MSDS for specified conditions.
Incompatibility
Avoid contact with strong alkalis or alkaline earth metals, finely powdered metals such as aluminum, magnesium or zinc and strong
oxidizers, since they may react or accelerate decomposition.
Hazardous Decomposition Products
Thermal decomposition products include hydrogen fluoride, hydrogen chloride,
carbon monoxide, carbon dioxide and chlorine.
10
Storage conditions: Keep valves tightly closed. Store in cool, dry well ventilated place. Temperature not to exceed 45oC. Suitable packaging: Store in original cylinder only.
Protect from contamination.