Quick Details
- Processing Time:-
- Port:-
- Supply Ability: -
- Brand Name:-
Product Description
Brief Introduction:
Low-temperature circulating pump also know as Low temperature cooling water/ liquid circulation pump. This device adopt mechanical refrigeration, the main function is
providing low temperature liquid, low temperature water bath . It can also connect with rotary evaporator, vacuum freeze drying oven , cycle water vacuum pump , magnetic stirrer and so on ,
to achieve the chemical reaction or drug store under low temperature condition.
Large cryogenic cooling liquid circulating pump is constant flow, constant voltage. Used for purification of high purity metals, rare element, environment experiment and magnetron
sputtering, vacuum coating and other large equipment, and also can meet the cooling demand of electron microscopy, electron probe, ultra high vacuum sputtering apparatus, X-ray machine, laser
and accelerate the electric light those high value equipment. Cryogenic cooling liquid circulating pump is particularly suitable for the chemistry, biology, physics laboratory work under
normal conditions or need to maintain a low temperature. It is a necessary lab equipment for medicine, chemical industry, food industry, metallurgical industry, universities, scientific
research, genetic engineering, polymer engineering and so on . (Can be customized large capacity according to user needs ).
Product Features:
1. Air-cooled and hermetically sealed compressor units (import) with dependable quality;
2. The dedicated and high-quality relays, protective devices and capacitors of the refrigerating units;
3. Digital Read Out of temperature and microprocessor controller for temperature, simple and easier to see;
4. It can be matched with a variety of instruments (rotary evaporators, fermentation tanks, chemical reactors, freeze-drying equipments, pharmaceutical reactors,
etc.);
5. Bigger cooling capacity and faster cooling speed, which have greatly improved the working efficiency;
6. It can effectively ensure the normal use of all kinds of precision instruments under the working conditions such as lacking water, the poor quality,pressure and
temperature of water, and high temperature;
7. The flow of circulating pump can be either adjusted or customized, which has greatly met the actual needs of different customers;
8. All models of this machine can be matched reasonably between the low temperature and the cooling capacity or capacity basing on the requirements of
customers.
Model
DLSB-20/20
Storage Volume
20L
No load minimum temperature(?)
-24
Refrigerating capacity
3255~990W
Coolant Temperature
-20?
Rated power
230W
Voltage
220V/60Hz
Flow
20L/h
Lift
4~6m
Temperature Precision
±0.2(?)
Weight
35KG
Dimensions
500*450*780mm
◊ Original full closed compressor unit, circulating pump of international famous manufacturer, advanced performance, reliable quality.
◊ Refrigeration unit special relay, protection, capacitor, refrigeration parts, are imported high-quality original device;
◊ Digital temperature display, microcomputer temperature controller, simple operation, eye-catching.
◊ Circulation system uses anticorrosive material, have rust and corrosion resistant; have the function to reduce liquid pollution.
◊ With an electric stirrer in the machine and be stirred directly.
◊ (40)-(60) °C, under the condition of the experiment, the cooling liquid can be transported to the use of place; there is a circulating pump inside.
Technical Parameters:
Various Types of Cool Chiller
According to the volume of cryogenic cooling bath circulation pump divided into : 5L,10L,20L,30L,40L,50L,60L,80L,100L.
Each volume according to the lowest temperature can divide into : -10?,-20?,-25? ,-30?,-40?,-60?, -80?,-120?.
Model
DLSB-10/10
DLSB-10/20
DLSB-10/25
DLSB-10/30
DLSB-10/40
DLSB-10/60
DLSB-10/80
DLSB-10/120
Refrigerant
Performance
Volume
10L
No Load
Min. Temp. (?)
-14
-23
-28
-32
-42
-62
-82
-122
Cooling
Capacity (W)
1894-884
2733-813
3256-990
2036-1022
2628-748
3679-510
3679-160
4997-120
Circulating
Performance
Flow
20L/min
Lift
4-6m
Temperature
Control
Performance
Coolant
Temp. (?)
-10
-20
-25
-30
-40
-60
-80
-120
Temp.
Precision (?)
±0.2
Working
Condition
Power
Supply (V)
220
220
220
220
220
220/380
220/380
380
Environment
Temp (?)
25
Environment
Humidity
(60-80%) Ventilation
Machine
Dimensions
Length (mm)
500
550
550
580
580
730
880
900
Width (mm)
400
420
420
450
450
660
670
700
Height(mm)
650
680
680
680
680
880
900
900
Please read it carefully before using the instrument:
1. The machine's power standard is 220 v, should be equipped with reasonable grounding system and the safety of the standard three pole socket.
2. Before use, please put into the liquid medium (water, alcohol, antifreeze can also be), medium level should not lower than cold tube and 20 mm below the workbench
is advisable. Don't let sand , acid-base class material or debris into the cooling system or the circulation pump, to prevent clogging or corrosion liner and
coil.
3. Recurring observe the slot liquid level height, when the liquid level is too low, should be timely to add liquid medium.
4. When pump working temperature is lower, should pay attention not to open the cover. Never put your hand into the groove, to prevent frostbite.
5. The Pump working environment, temperature ≤ 25 ° C , humidity ≥ 60 ?, no obstacles in the instrument around 300 mm. Indoor open flame is strictly
prohibited.
6. When the liquid outer loop, the client shall pay special attention to the robustness of the out pipe joint, fight off, in order to avoid liquid leakage.
7. After use, all switch should be closed and cut off power supply.
8. The instrument should be regular cleaning, if the pump unused for a long time, you should put out the medium, and deep clean, maintain a clean and tidy work in
mesa and the operation panel.
9. Don't try to open and repair equipment personal, any question, just make a call !