60TPH Water Purifier Reverse Osmosis System Waste Water Treatment Plant

FOB Price: Get Latest Price
|
- (Min. Order)
  • Supplying Ability-
  • Supplying TypeOem service
  • Model Number-
  • Preferred Payment Method:-

Quick Details

  • Processing Time:-
  • Port:-
  • Supply Ability: -
  • Brand Name:-
Product Description 60TPH Water Purifier Reverse Osmosis System Waste Water Treatment Plant RO Water Treatment System(reverse osmosis system) includes high-pressure pump, reverse osmosis membrane element, pressure vessel (membrane shell), cleaning system and control instrument, applying membrane separation technology to remove charged ions, inorganic substances, colloidal particles, bacteria and organic substances in water. The desalination rate of the whole system can reach 96%-99%, making the conductivity of the permeated water < 10 us/cm. Concentrated water will not pollute the environment.   Specifications of Ro Water Treatment System Model JFRO-60T Host Size 7200x1500x1800mm (can be customized) Power 45KW Power Supply 220V /380V/460V - 50Hz/60Hz,220V 50Hz can be customized Operating Pressure 1.2-1.5MPa Recovery Rate 70% Designed Water Inlet 85t/h Outlet Flow 60t/h Desalination Rate ≥99.5% RO Frame SUS304/Carbon Steel (Optional) Membrane Size 8040 Membrane Elements DOW /Hydranautics/Troy/ Vontron (Optional) Number of Membranes 60 Raw Water Pump CNP/NYP/GRUNDFOS (Optional) High Pressure Pump CNP/NYP/GRUNDFOS (Optional) Tank Material SS/FRP(Optional) Control Valve Manual/Automatic Control Valve Brand FLECK/RUNXIN Membrane Housing FRP Number of Membrane housing 10 Pipe Material U-PVC/ Stainless steel (Optional) Working Principle of Ro Water Treatment System Using a special high-pressure water pump, the raw water is added to a pressure of 6-20 kg, so that the raw water permeates the reverse osmosis membrane with a pore size of only 0.0001 microns under the action of pressure. Chemical ions, bacteria, fungi, and virions cannot pass through, and are discharged with wastewater. Only water molecules and solvents with a volume of less than 0.0001 microns are allowed to pass through.   Composition of Ro Water Treatment System 1, the pretreatment system generally includes the original water pump, dosing device, quartz sand filter, activated carbon filter, precision filter, etc. Its main function is to reduce the pollution index of raw water and other impurities such as residual chlorine to meet the requirements of reverse osmosis inlet water. 2. Reverse osmosis device mainly consists of multistage high pressure pump, reverse osmosis membrane element, membrane shell (pressure vessel), bracket and so on. Its main function is to remove impurities in water, so that the water meets the requirements of use. 3. Post-treatment system is an additional configuration in the case that reverse osmosis cannot meet the requirements of outlet water. Mainly including negative bed, positive bed, mixed bed, sterilization, ultrafiltration and other one or more of the equipment. 4, cleaning system is mainly composed of cleaning water tank, cleaning water pump, precision filter. When the reverse osmosis system is polluted and the effluent index cannot meet the requirements, it is necessary to clean the reverse osmosis system to restore its efficacy. 5. Electrical control system is used to control the normal operation of the whole reverse osmosis system. Including instrument panel, control panel, all kinds of electrical protection, electrical control cabinet, etc.   Process flow Of Ro Water Treatment System Original water pump → mechanical filter (quartz sand filter)→ activated carbon filter → sodium ion exchanger (water softener)→ security filter → high pressure pump → reverse osmosis → ozone sterilizer (ultraviolet sterilizer) Unique features of Ro Water Treatment System 1. The desalination rate of reverse osmosis equipment is high, and the desalination rate of single membrane can reach 99%. The desalination rate of primary reverse osmosis system can generally be stabilized above 90%, and the desalination rate of secondary reverse osmosis system can generally be stabilized above 98%. 2. Because reverse osmosis equipment can effectively remove microorganisms, organic matter and inorganic matter such as iron and silicon, the quality of effluent is much better than other methods. 3. The equipment has small footprint, compact structure, reliable operation and good water quality. 4. The system is simple, easy to operate, high degree of automation, automatic shutdown when fault occurs, and has automatic protection function. 5. The recovery rate is high, up to more than 70%. 6. Save the chemical consumption cost, labor cost and waste water treatment cost generated by regeneration, and reduce environmental pollution. Application of Ro Water Treatment System 1. Purification of pure water, distilled water and food and beverage water. 2. Electronic, pharmaceutical, food and other industries of pure water, ultrapure water preparation. 3. Separation, concentration and liquid decolorization process engineering in light textile, chemical and food industries. 4. Desalinated seawater and brackish water Photos of Ro Water Treatment System  

You May Be Intrested In