Efficient Multi-Channel Digital Input Ethernet Remote Acquisition Module M410T

FOB Price: Get Latest Price
|
- (Min. Order)
  • Supplying Ability1500 Units Per Month
  • Supplying TypeOem service
  • Model NumberM410T
  • Preferred Payment Method:T/T, L/C, D/A, D/P, Western Union, Money Gram, PayPal

King Pigeon Communication Co., Ltd

China

Port: ShenZhen port

Quick Details

  • Product name:Multi-Channel Digital Input Ethernet Remote Acquisition Module
  • Sensor Type:Wet contact (NPN or PNP), Dry Contact
  • I/O Mode:1*RJ45+1RS485+16DIN
  • Counter Frequency:700khz(Only the 1st Channel can be used as high speed pulse counter)
  • LAN:Ethernet 10/100 Mbps, RJ45 por
  • LAN Protocols:TCP, TCP/IP,TCP Server,TCP Client
  • Serial Port:RS485+RJ45
  • Modbus Slave address:Modbus Slave address
  • Serial Port Protection:Serial Port Protection
  • Dimensions:L105 * W88 * H30mm
  • Processing Time:15 Days
  • Port:ShenZhen port
  • Supply Ability: 1500 Units Per Month
  • Brand Name:King Pigeon
Efficient Multi-Channel Digital Input Ethernet Remote Acquisition Module M410T  Specifications Ethernet Remote I/O Module Specifications • Digital Input Sensor Type Wet Contact (NPN or PNP), Dry Contact I/O Mode DI or Event Counter Dry Contact • On: short to GND=0 • Off: open=1 Wet Contact (DI to COM) • On: 10 to 30 VDC =1 • Off: 0 to 3 VDC=0 Counter Frequency 700khz(Only the 1st Channel can be used as high speed pulse counter) Digital sampling frequency 500Hz Digital filtering strategy Continues 3 times Isolation Optical Isolated,3k VDC or 2k Vrms • Digital Output Type Sink I/O Mode DO  Pulse Output Frequency 10Hz~300KHz(Only the 1st Channel can be used as high speed pulse outputs) Over-Voltage Protection 50 VDC Over-Temperature Shutdown 175°C (typical), 150°C (min.) Load Current  Max. 500 mA per channel Digital sampling frequency 500Hz • Analog Input Type Differential input Resolution 12 bits I/O Mode Voltage / Current (jumper selectable) Input Range 0 to 10 VDC, 0 to 20 mA, 4 to 20 mA, 4 to 20 mA Accuracy ±0.1% FSR @ 25°C ±0.3% FSR @ -10 and 60°C ±0.5% FSR @ -40 and 75°C Sampling frequency 20Hz Isolation Electrical isolation • Working Power Requirements Input Voltage 12 to 36 VDC, Peak Voltage:+40VDC, Power consumption: Less than 3W; Input Current 139 mA @ 24 VDC • Power Output Output Voltage 12 to 36 VDC Output Current 139 mA @ 24 VDC • LAN Ethernet 10/100 Mbps, RJ45 ports Protection 15KV ESD Protection Protocols Modbus TCP, TCP/IP,TCP Server,TCP Client  Max. TCP Connection 5 • Serial Port RS485 MODBUS- RTU Protocol, Modbus-ASCII Protocol, Modbus Master or slave. Protection 15KV ESD Protection Modbus Slave address 1~255 Baud Rate 1200,2400,4800,9600,19200,38400,57600,115200,128000Bps; Mapping registers Bit Type: 300 Registers, 16-Bit Type: 300 Registers. • Physical Characteristics Wiring I/O cable max. 14 AWG Dimensions 105 x 88 x 30 mm Weight Under 205 g Mounting DIN rail or wall • Environmental Limits Operating Temperature Standard Models: -10 to 60°C (14 to 140°F) Wide Temp. Models: -40 to 75°C (-40 to 167°F) Storage Temperature -40 to 85°C (-40 to 185°F) Ambient Relative Humidity 5 to 95% (non-condensing) Altitude Up to 3000 m The 16CH Digtial Input Module M410 Ethernet Remote I/O Module is an industrial class, isolated designed, high reliability, high stability and high precision data acquisition module, embedded 32-Bit High Performance Microprocessor MCU, Integrated 1 Industrial 10/100M adaptive Ethernet module inside. It provides multi I/O, supports standard Modbus TCP, can be intergraded into SCADA, OPC server, and other automation systems. It is design for working in the harsh industrial application environment, widely used in a variety of industrial automation, security monitoring system, automatically measurement and control system. The 16CH Digtial Input Module M410 Ethernet Remote I/O module provides a RS485 interface, through the RS485 bus, it can cascade Modbus RTU I/O devices or Modbus RTU meters, e.g.: a variety of digital input or digital outputs, analog inputs or outputs, thermal resistance IO module combination, save costs. At the same time, the Ethernet Remote I/O module has register mapping function, the cascade Modbus RTU I/O data are automatically collected to the mapping memory area, the Modbus TCP Client query without waiting then can get a quick response to meet the industrial timely requirements. The 16CH Digtial Input Module M410 Ethernet Remote I/O module provides 16 optical-isolated digital inputs, supports max. 700KHz high speed pulse counter. All of the I/O with high sampling frequency and special filtering strategy to ensure it’s reliable. Detail Features: 1. Embedded 32-Bit High Performance Microprocessor MCU, inbuilt watchdog; 2. Wide range power supply 12 ~ 36VDC with over voltage and phase-reversal protection; 3. Management and configuration via LAN connection configuration software for easy operation and maintenance; 4. Integrated 1-2 10/100M adaptive Ethernet module, supports Modbus TCP protocol; 5. 4 RTD input, supports PT100 and PT1000 resistance sensor, compatible 2 or 3 wires; 6. High sampling frequency and special filtering strategy to ensure reliability; 7. 1 RS485 Serial port, supports Modbus RTU/ASCII Master, can extend I/O modules; 8. Supports register mapping function and extend I/O inquiry strategy; 9.Provides 1 channel 12~36VDC power source output for external device, saving wiring cost; 10.LED instructions work status, with reset button to reset, easy on-site installation and commissioning; 11.Using metal shell, protection class IP30. Metal shell and system security isolation, especially suitable for industrial applications in the field; 12.Small size, L105 * W88 * H30mm, compatible wall installation and DIN35mm industrial rail installation. Typically applications: 1.      BTS Monitoring; 2.      Security Alarm System applications;           3.      Supervision and monitoring alarm systems; 4.      Automatic monitoring system;              5.      Vending Machines security protection; 6.      Pumping Stations, Tanks, Oil or Water levels; 7.      Buildings and Real Estate; 8.      Weather Stations;  9.      River Monitoring and Flood Control; 10.   Oil and gas pipelines;   11.   Corrosion protection 12.   Temperatures, water leakage applications; 13.   Wellheads, boat, vehicle; 14.   Energy saving, street lights control system; 15.   Valve controls; 16.   Transformer stations;    17.   Unmanned machine rooms; 18.   Control room application; 19.   Automation System, M2M; 20.   Access Control System; 21.  PLC Gateway, PLC Remote Monitoring.