Quick Details
- Processing Time:-
- Port:-
- Supply Ability: -
- Brand Name:PEPPERL+FUCHS
1-channel isolated barrier
115 V AC supply
Dry contact or NAMUR inputs
Relay contact and transistor output
Adjustable output timer functions from 10 ms ... 60 min
Input frequency up to 80 Hz, pulse divider up to 1 kHz
Reset function
Configurable by keypad
Line fault detection (LFD)
This isolated barrier is used for intrinsic safety applications. It is a highly configurable timer that accepts a digital signal (NAMUR sensor/mechanical contact) from a hazardous area and is
commonly used in applications requiring on-delay, off-delay, one-shot, or pulse lengthening. The output relay switch duration is easily adjusted, and a pulse divider function allows step-down
ratios from 1:1 to 9999:1. A reset can be activated via dry contact switch and used to terminate a particular time function. The unit is easily programmed by the use of a keypad located on the
front of the unit. Line fault detection of the field circuit is indicated by a red LED. For additional information, refer to the manual and .
General specifications
Signal type
Digital Input
Supply
Connection
terminals 23, 24
Rated voltage
115 V AC ± 10 %
Rated current
35 mA
Power consumption
4 VA
Input
Connection side
field side
Connection
Input I: terminals 1+, 3- , input II: terminals 13+, 14-
Input I
acc. to EN 60947-5-6 (NAMUR), see manual for electrical data
Open circuit voltage/short-circuit current
8.2 V / 10 mA
Switching point/switching hysteresis
1.2 ... 2.1 mA / approx. 0.2 mA
Pulse duration
min. 75 µ,s / 1 ms see instruction manuals, the maximum input frequency has to be observed.
Input frequency
0 ... 80 Hz , pulse divider 0 ... 1 kHz
Line fault detection
breakage I &le, 0.15 mA, short-circuit I > 6.5 mA
Input II
reset
Active/Passive
I > 3 mA / I < 1.5 mA
Open circuit voltage/short-circuit current
12 V / 3.5 mA
Pulse duration
min. 10 ms
Output
Connection side
control side
Connection
output I: terminals 10, 11, 12 , output II: terminals 19+, 20-
Output I
signal , Relay output
Contact loading
253 V AC/ 2 A / cos &phi, &ge, 0.7 , 40 V DC/ 2 A
Mechanical life
5 x 107 switching cycles
Energized/De-energized delay
approx. 20 ms / approx. 20 ms
Output II
signal , electronic unit, isolated
Contact loading
40 V / 50 mA
Energized/De-energized delay
after rising input flank 3 ms , after falling input flank 2 ms
Signal level
1-signal: (L+) -2.5 V (50 mA, short-circuit/overload proof) 0-signal: blocked output (off-state current &le, 10 µ,A)
Transfer characteristics
Input I
Resolution
< 0.1 % of the set value, min. 10 ms
Accuracy
2 ms
Influence of ambient temperature
0.003 %/K (50 ppm)
Galvanic isolation
Input I/other circuits
reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Output I/power supply and reset
reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Output I, II against eachother
reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Output II/power supply
reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Output II/reset
basic insulation according to IEC/EN 61010-1, rated insulation voltage 50 Veff
Reset/power supply
reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Indicators/settings
Display elements
LEDs , display
Control elements
Control panel
Configuration
via operating buttons
Labeling
space for labeling at the front
Directive conformity
Electromagnetic compatibility
Directive 2014/30/EU
EN 61326-1:2013 (industrial locations)
Low voltage
Directive 2014/35/EU
EN 61010-1:2010
Conformity
Electromagnetic compatibility
NE 21:2006
Degree of protection
IEC 60529:2001
Ambient conditions
Ambient temperature
-20 ... 60 °C (-4 ... 140 °F)
Mechanical specifications
Degree of protection
IP20
Connection
screw terminals
Mass
approx. 300 g
Dimensions
40 x 119 x 115 mm (1.6 x 4.7 x 4.5 inch) , housing type C3
Mounting
on 35 mm DIN mounting rail acc. to EN 60715:2001
Data for application in connection with hazardous areas
EU-type examination certificate
TÜV 99 ATEX 1408
Marking
II (1)G [Ex ia Ga] IIC II (1)D [Ex ia Da] IIIC I (M1) [Ex ia Ma] I
Supply
Maximum safe voltage
253 V AC (Attention! The rated voltage can be lower.)
Input I
terminals 1+, 3-: Ex ia
Voltage Uo
10.1 V
Current Io
13.5 mA
Power Po
34 mW (linear characteristic)
Input II
terminals 13+, 14- non-intrinsically safe
Maximum safe voltage Um
40 V (Attention! The rated voltage can be lower.)
Output I
terminals 10, 11, 12 non-intrinsically safe
Contact loading
253 V AC/2 A/cos &phi, > 0.7, 40 V DC/2 A resistive load (TÜV 99 ATEX 1408) 50 V AC/2 A/cos &phi, > 0.7, 40 V DC/2 A resistive load (TÜV 02 ATEX 1885 X)
Maximum safe voltage
253 V (Attention! The rated voltage can be lower.)
Output II
terminals 19+, 20- non-intrinsically safe
Maximum safe voltage
40 V (Attention! The rated voltage can be lower.)
Certificate
TÜV 02 ATEX 1885 X
Marking
II 3G Ex nA nC IIC T4 Gc
Output I
Contact loading
50 V AC/2 A/cos &phi, > 0.7, 40 V DC/1 A resistive load
Galvanic isolation
Input I/other circuits
safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V
Directive conformity
Directive 2014/34/EU
EN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 60079-15:2010
International approvals
FM approval
Control drawing
116-0305
UL approval
E223772
IECEx approval
IECEx TUN 03.0000
Approved for
[Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I
General information
Supplementary information
Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see .