Quick Details
- Standard:Number of cores: 3
- Cabe Size:25sqmm-1800sqmm
- Certification:CCC ISO CE
- Special requiremets:Fire-resistant, flame retardant, low smoke
- Voltage:11KV high voltage power cable
- Name:China
- Processing Time:3-5 work days
- Port:Qingdao, Tianjing
- Supply Ability: 100000 Meters Per Week
- Brand Name:Guowang
Applications of 11KV Medium Voltage
Cable Price
Used for power transmission and distribution line with voltage rated at 35kV and
below.
Compared with PVC Insulated Power Cable, xlpe power cable boasts not only
characteristics of excellent electricity, mechanism, heat and aging-resistant, environment stress-resistant and chemical corrosion-resistant, but also simple structure, light weight, no
restriction by laying drop, and high temperature allowance for long-term working.
Standards of 11KV Medium Voltage
Cable Price
International: IEC 60502-2, IEC 60228
China:
GB/T 12706.2-2008
Other standards such as BS,DIN and ICEA upon request
Rated
Voltage:
6/10kV,
6.35/11kV (12kV), 8.7/15kV, 12/20kV, 18/30kV,19/33kV
Core
Number:
Single Core or
Three Core (1C or 3C)
Available
Dimensions:
25mm2, 35mm2,
50mm2, 70mm2, 95mm2, 120mm2, 150mm2, 185mm2, 240mm2, 300mm2, 400mm2, 500mm2, 630mm2.
Codes
Available:
N2XSY, N2XSEY,
NA2XSY, NA2XSEY, N2XSRY, NA2XSRY, N2XSEBY, N2XSEYBY, NA2XSEBY, N2XSERY, NA2XSERY, N2XSEYRGbY, NA2XSEYRGbY, N2XS(F)2Y, NA 2XS(F)2Y, N2XS(FL)2Y, N2XSH, N2XSYRY
YJV, YJLV,
YJSV, YJLSV, YJV72, YJLV72, YJSV72, YJLSV72, YJV22, YJLV22, YJSV22, YJLSV22, YJV32, YJLV32, YJSV32, YJLSV32
Application:
For power
networks, underground, outdoors and in cable ducting. It is recommended that the installation instructions indicated by the Local Electric Code, or any equivalent, be followed, so that
the safeguarding of persons and the integrity of the product will not be affected during installation.
Construction:
Conductor:
Stranded round
compacted copper or aluminum conductor (Cu / Al ), copper wire annealed.
Conductor
Screen:
Semi-conducting
material
Insulation:
XLPE
(Cross-Linked Polyethylene)
Insulation
Screen:
Semi-conducting
material
Metallic
Screen:
Copper tape
screen or copper wire screen (CTS / CWS )
Filler:
PP rope
Separator:
Binding
tape
Bedding:
PVC (Polyvinyl
Chloride)
Armouring:
Single Core:
Aluminium Wire Armoured (AWA) Multi-core: Steel Wire Armoured (SWA) or Steel Tape Armoured (STA)
Sheath:
PVC (Polyvinyl
Chloride), flame retardant PVC, PE, LSOH, HFFR
Colour:
Red or
Black
Temperature
Rating:
0°C to
90°C
Minimum Bending
Radius:
Single Core: 15
x overall diameter Three Core: 12 x overall diameter (Single Core 12 x overall diameter and 3 core 10 x overall diameter where bands are positioned adjacent to joint or terminations
provided that the bending is carefully controlled by the use of a former)
Rated voltage(KV)
3.6/6
6/6
6/10
8.7/10
8.7/15
12/15
12/20
18/20
18/30
21/35
26/35
Core Number
1 core, 3 core
Cross-section
mm2
1C
25~800
35~800
3C
25~400
35~400
b) IEC/BS/DIN standard
Rated voltage(KV)
3.6/6
6/6
6/10
8.7/10
8.7/15
12/15
12/20
18/20
18/30
21/35
26/35
Core Number
1 core, 3 core
Cross-section
mm2
1C
25~800
35~800
3C
25~400
35~400
c) ASTM standard
Rated voltage(KV)
5001-8000
8001-15000
15001-25000
25001-28000
28001-35000
35001-46000
1 core, 3 core
Cross-section
mm2
1C
6AWG~1600kcmil
2AWG~1600kcmil
1AWG~1600kcmil
2AWG~1600kcmil
1/0AWG~1600kcmil
3C
6AWG~1600kcmil
2AWG~1600kcmil
1AWG~1600kcmil
2AWG~1600kcmil
4/0AWG~1600kcmil