Quick Details
- Processing Time:-
- Port:-
- Supply Ability: 3000 Kilometers Per Month
- Brand Name:-
This type of outdoor cables is designed for aerial installation, it can be suspended between buildings, on posts and masts of communication lines and power lines with the maximum
value of the electric fi eld potential of 12 kV and 25 kV. The outer sheath is UV-resistant and at the same time provides protection against environmental infl uences, such as snow,
ice, sun insolation and wind.
In accordance with the customer requirements additional parameters of the cables can be implemented: - tracking resistance up to 25
kw; cable identification: IKAT-... . - lightweight design (without intermediate
coating); cable identification: IKAL-... (IKALc). - IKA (IKAL) cable design contain aramid strength yarns, IKAc (IKALc) glass yarns.
GENERAL CHARACTERISTICS
Cable type
IKA…М…
IKAc-M…
IKAL..М…
IKALc...M…
Design
Multi-tube
Multi-tube
Multi-tube
Multi-tube
Number of optical fi bers in the cable
to 288
to 288
to 288
to 288
Number of tubes around central strength member
4-24
4-24
4-24
4-24
Minimum outer cable diameter, mm
11,1
11,2
9,0
9,0
Minimum weight, kg/km
97
105
85
95
Minimum long-term tension, kN
3,0
3,0
1,0
1,0
Minimum crush resistance, kN/cm
0,3
0,3
0,3
0,3
Minimum allowed impact resistance, J.
5
5
5
5
Minimum bending radius
20 cable diameter
20 cable diameter
20 cable diameter
20 cable diameter
Operating temperature range, °С
from -60 to +70
from -60 to +70
from -60 to +70
from -60 to +70
Minimum Installation temperature, °С
-30
-30
-10
-10