IEC 60870-5-104

FOB Price: Get Latest Price
|
- (Min. Order)
  • Supplying Ability-
  • Supplying TypeOem service
  • Model Numberv21.03.026
  • Preferred Payment Method:T/T, L/C, D/A, D/P, Money Gram, PayPal, Other

Quick Details

  • Processing Time:-
  • Port:-
  • Supply Ability: -
  • Brand Name:-
 IEC60870-5-104 FreyrSCADA offering  1) IEC104 Server Simulator 2) IEC104 Client Simulator 3) Static and Dynamic Libraries 4) IEC104 Source Code Library 5) Demo Kit (Raspberry Pi & BeagleBone Black) or Customer specific Hardwarewindows, Linux, QNX DownloadEvaluation Kit - IEC 60870-5-104 Development Bundle New updated Version of IEC 60870-5-104 Simulator & SDK (Software Development Kit) is available now.  In the Development Bundle, We included IEC 60870-5-104 Server & Client Simulator, Windows & Linux SDK. IEC60870-5-104 IEC 60870-5-104 Server Simulator IEC 60870-5-104 Client Simulator IEC 60870-5-104 Windows Software Development Kit(SDK) IEC 60870-5-104 Linux Software Development Kit(SDK) For business inquiries Please email to  Product Specification IEC60870-5-104 Stack Source code library Features Written in ANSI-Standard C Source Code, under a strict corporate coding standard, and supports C++, C# Can be used with or without a Real Time Operating System (RTOS). Transparent licensing scheme - No hidden costs, No deferred payments. High performance, robust and scalable architecture Provides a simple method for systems Integrators and OEMs to utilize standard tools to implement their systems Our stacks are fully compliant with "POSIX" and tested in ubuntu, feroda, Debian, QNX, Linux Embedded OS and Various Cross compiler tool chains. Our all protocol stack supports "POSIX compliant operating system" Context-based event-driven model Multiple Server and Client Simulation In a Single Server(link) simulate Multiple Stations (Common Address) Supports Background Scan, Cyclic Data Transmission, Double Transmission, Redundancy and File transfer. Communication with redundant control systems and interruption-free switch over between redundant systems Supports "Select-Before-Operate" and "Direct-Execute" command execution modes In IEC 60870-5-104 Client Side, Data Mode and Test mode connection type available. IEC60870-5-104 Windows Software Development Kit (SDK) FreyrSCADA IEC 60870-5-104 Demo Win DLL includes simple (Server & Client C programs )example using a Command window and command line inputs.  The source code will allow you to quickly compile your own examples with the features of your existing development environment to work with our IEC 60870-5-104 DLL.  FreyrSCADA IEC 60870-5-104 Windows SDK contains Win DLL (precompiled library), Static link lib, Demo IEC104 Server & Client programs, Visual Studio Demo console project files, Doxygen .  We used Visual studio compiler to create the dll, sample test projects. This evaluation package allows you to: Access product manual(API documentation)(pdf, Doxygen html) Browse the IEC 60870-5-104 library API documentation Study the source code of the IEC 60870-5-104 examples provided Modify and compile the IEC 60870-5-104 examples Create your own IEC 60870-5-104 programs and test with leading test tools like (ASE,...) You can use the source code of the application examples and modify them according to your needs. Minimum system requirements: Windows XP, Vista, Windows 7, 8 and 10 Visual studio / Any IDE supports C & C++ Programming IEC60870-5-104 Linux Software Development Kit (SDK) FreyrSCADA IEC 60870-5-104 Demo Linux Shared Library includes simple (Server & Client C programs )example using a Command window and command line inputs.  The source code will allow you to quickly compile your own examples with the features of your existing development environment to work with our IEC 60870-5-104 library.  FreyrSCADA IEC 60870-5-104 Linux SDK contains Shared Library(.a) (precompiled library), Static link lib, Demo IEC104 Server & Client programs, CodeBlock Demo console project files, Doxygen .  We used gcc compiler to create the Shared Library, sample test projects.  gcc Compiler Version: gcc 4.6.3 - i686.  This evaluation package allows you to: Access product manual(API documentation)(pdf, Doxygen html) Browse the IEC 60870-5-104 library API documentation Study the source code of the IEC 60870-5-104 examples provided Modify and compile the IEC 60870-5-104 examples Create your own IEC 60870-5-104 programs and test with leading test tools like (ASE,...) You can use the source code of the application examples and modify them according to your needs. Minimum system requirements: Ubuntu, Feroda, Debian...(All Posix Compliant Operating Systems) gcc - Any IDE supports C & C++ Programming IEC60870-5-104 Server Simulator reyrSCADA IEC 60870-5-104 Server Simulator was originally developed to test the IEC 60870-5-104 stack.  We developed the stack to run multiple hardware platform (windows, Linux, RTLinux, QNX..). So we had to test multiple platform. At that time, our engineers, developed the test simulation application.  We tested this simulator with multiple test software available in the market.  Our support team has young, dynamic and professional team of engineers. Our Engineers will provide the quick and accurate solution as per customer requirement.  We can add up to 50 server node in the simulator. Every server node will work independently.  Simulator window shows the status & connection ip address, port number, redundancy enabled or not,If Redundancy enabled it shows, the redundant source ip address, port .  The user can update the monitoring Point information.The following parameters can change Value and quality bits.    Features Multiple Server Simulation In a Single Server(link) simulate Multiple Stations (Common Address) Redundancy Enabled Mapping of Control Point to monitor Information point, consider C_SC point can map to M_SP point Communication with redundant control systems and interruption-free switchover between redundant systems Supports "select-before-operate" or "direct-execute" command execution modes supports File Transfer, Directory commands Minimum system requirements: Windows XP, Vista, Windows 7, 8 and 10 IEC60870-5-104 Client Simulator FreyrSCADA IEC 60870-5-104 Client Simulator was originally developed to test the IEC 60870-5-104 stack.  We developed the stack to run multiple hardware platform (windows, Linux, RTLinux, QNX..). So we had to test multiple platform. At that time, our engineers developed the test simulation application.  We tested this simulator with multiple test software available in the market.  Our support team has young, dynamic and professional team of engineers. Our Engineers will provide the quick and accurate solution as per customer requirement.  We can add up to 50 Client node in the simulator. Every Client node will work independently.  Simulator window shows the Connection status & connection ip address, port number.    Features Multiple Master / Client Simulation In a Single Client(link) simulate Multiple Stations (Common Address) Data Mode, and Test mode connection type available Supports "Select-Before-Operate" SBO or "Direct-execute" command execution modes supports File Transfer, Directory commands Minimum system requirements: Windows XP, Vista, Windows 7, 8 and 10 YoutubeIEC 104 Server and Client Simulator Video tutorial Linkedin- IEC 60870-5-104 Blog - IEC 104 Facebook - IEC60870-5-104