Point Of Use Ionizing Blower_DC0601C

FOB Price: USD 160
|
1 Units (Min. Order)
  • Supplying Ability-
  • Supplying TypeOem service
  • Model NumberDC0601C
  • Preferred Payment Method:T/T, L/C, D/A, D/P, PayPal

ESDMAN CO.,LTD

China

Port: -

Quick Details

  • Processing Time:-
  • Port:-
  • Supply Ability: -
  • Brand Name:ESDMAN
Safety: 1. Do not disassemble the product without permission. 2. Do not use in dangerous environment. ( such as flammable and explosive ) 3. Do not use in place with plenty of oil or water, high temperature and humidity, especially in places with condensation. Product Description: 1. Adopting steady-state DC ionization technology, it is generally used to deal with static electricity problems during assembly, testing, and packaging. It can also be installed in equipment to provide rapid static elimination in a limited space to solve static electricity generated during high-end manufacturing processes. 2. Steady-state DC ionization technology has the following advantages:  ①Compact body design, light weight  ②Both sides buckles design, can lock the blowing angle   ③Stable ion balance  ④Longer cleaning and maintenance intervals  ⑤No need for grounding, easy installation  ⑥The emitter tip has high-voltage shielding technology to avoid electric field induction charging, In the case of low wind speed, it can provide faster static dissipation speed, low wind speed and low noise, which will not cause much noise to the production environment, making the operator more comfortable. Installation: Insert the DC head of the attached power adapter into the power port on the back of the instrument, connect the power adapter to the AC110-220V socket, the POWER green indicator light is on, and the instrument is running normally. Installation Method: 1. Use M6 screws and nuts to fix the bottom bracket of the fan at an appropriate position that needs to eliminate static electricity.  2. When using more than two ionizers, make sure to keep a distance of at least 100mm between the two.  3. The distance from the air outlet needs to be at least 100mm away from static objects, and reverse charging may occur within 100mm. 4. The ionizer is at least 300mm away from the metal conductor, and the air inlet is at least 150mm away from the wall and other objects. Routine Maintenance: Cleaning of the discharge emitter 1. After the discharge emitter is used for a long time, there will be dust and other pollutants in and around the discharge emitter. 2. Use cotton swabs to remove contaminants. 3. The discharge emitter should be cleaned regularly (approximately 100 hours of use need to be cleaned once). When the pollution is serious, the cotton swab can be cleaned with alcohol. Be careful not to damage the discharge emitter when cleaning. Abnormal Alarm: When the high pressure is abnormal, the red light of ALARM will prompt the operator to overhaul the fan.

You May Be Intrested In