Quick Details
- Processing Time:10 days
- Port:Qingdao
- Supply Ability: 200 Tons Per Month
- Brand Name:Risol
AMPS FLUID
LOSS ADDITIVE
Risol
FL1300S
PHYSICAL AND CHEMICAL INDICATORS
Appearance
Bulk Density,
g/cm3
Water-Solubility
0.315mm Sieve (45 mesh)
Residues, %
White or faint yellow
powder
0.70±0.20
100%
<12
CEMENT SLURRY PRESCRIPTION
Cement Slurry
Density
Recommended Dosage in Fresh
Water and Moderate Temperature System
Recommended Dosage in 18%
Slat Water and Moderate Temperature System
Recommended Dosage in 18%
Salt Water and High Temperature System
1.90±0.01g/cm3 (in
fresh water, W/C=0.44,
in 18%
salt water, W/C=0.57)
0.6%(BWOC)
0.9%(BWOC)
2.0%(BWOC)
CEMENT SLURRY PERFORMANCE
Item
Test
Condition
Technical
Indicator
Fluid
loss,
ml
Fresh water
system
80oC,
6.9MPa
≤50
18% salt water
system
≤150
18% salt water
system
120oC,
6.9MPa
≤150
Initial consistency,
Bc
80oC/45min,
46.5MPa
≤25
40-100 Bc thickening time,
min
≤40
Thickening time,
min
50 -
150
Free fluid,
%
80oC, Atmospheric
Pressure
≤1.4
24h compressive strength,
MPa
≥14
.
FEATURES
Very effective fluid loss additive
with high purity and low dosage.
Provide Fluid loss control in low,
normal or high density cement slurris.
Temperature Range: 0-180oC(32-356oF,BHCT)