Quick Details
- Processing Time:30
- Port:Shenzhen
- Supply Ability: 4 Units Per Month
- Brand Name:Rata
- Model Number:R2500kW/L2000kvar
- Usage:generator testing
- Power:2500kW
- Place of Origin:China
- Brand Name:Rata
PRODUCT OVERVIEW
Rata resistive reactive load bank is used to test the rated power factor of engine generator. Power factor is a measure of the efficiency of converting load current into active power output. This
is a good indicator of the effect of load current on generator efficiency. This page shows the picture of rata 2500kW resistive reactive load bank
The structures of common resistive reactive load banks include:
Resistor - the resistor is connected in the row. Each cylinder bank is energized to simulate the linear load of the generator.
Inductor - the main component of the tester is the iron core reactive element. Externally wound copper coil or aluminum coil, when combined with resistance load tester, will produce lagging power
factor load.
Capacitor – the main component of this tester is the capacitor bank. Its working principle is similar to that of reactor system. The dielectric material in the capacitor changes the power factor
to the leading power factor. The load provided by the device simulates the typical electronic or nonlinear load in the telecommunications, computer or UPS industry.
PRODUCT PICTURE
APPLICATION SCENARIO
PARTIAL PARAMETERS
Note: all parameters are for reference only and can be customized
Product name
marine load bank
Specifications
R2500kW/L2000kvar/400V/690V
Load bank
Formation
Outdoor container type,resistive load,inductive load,data acquisition,electrical control part,heat dissipation device and load protection control
Test voltage
According to customer needs
Test frequency
50Hz/60Hz
Load character
Resistive inductive load,to meet the needs of multiple parallel work
Power factor
0.8
Load connection
Copper bar
Loading accuracy
±3%
Three phase balance
Inbalance: less than or equal to 3%
Working mode
Continuous work
Power supply
TN-C,380V/50Hz
Cooling mode
Forced air cooling, side air outlet or top air outlet
Insulation class
F
Accuracy
The sampling accuracy of the instrument is 0.2;
(Voltage:±0.5%,current:±0.5%,frequency:±0.1%,power:±1%,Cos:±1% )
Load expansion
Parallel expansion of multiple load containers
Voltage rising mode
Realized by transformer
Load protection
Short circuit, over voltage, over current, high temperature, air volume, emergency stop protection
Resistive
load
Minimum step
1kW
Load step
According to customer needs
Resistance tube
Insulation impedance of each resistance element DC1000V 20M Ω above,
withstand voltage AC2000V 1 minute,
Resistance error of each resistance tube:±3%
Resistive material
Special alloy resistor
Cold and hot state change
less than or equal to 2%
Inductive load
Minimum step
1kvar
Load step
According to customer needs
Inductor
Withstand voltage AC3000V 1 minute,
inductance error of each Inductor:±3%
Material
Aluminum reactor or copper reactor
Other
Protection level
IP56 when not in use, IP20 when in use
Use occasion
Outdoors
Transport
The box body has a load-bearing lifting hole, which meets the requirements of long-distance transportation
Color
Customized
Standard
Meet international standard, ship standard, military standard and telecommunication standard
Color
Customized
Ambient temperature
-20℃ to 50℃
Humidity
Up to 100%
Altitude
Up to 2500m
Atmospheric pressure
86 to 106kPa
MORE SPECIFICATIONS
Note: all parameters are for reference only and can be customized
Active power
(kW)
Inductive power
(kvar)
Apparent power
(kVA)
Voltage
(kV)
P.F.
Frequency
(Hz)
Size
(mm,L*W*H)
Weight
(Kg)
100
75
125
0.4/0.69
0.8
50/60
1500*1500
*1500
900
200
150
250
0.4/0.69
0.8
50/60
1700*1600
*1500
2000
300
225
375
0.4/0.69
0.8
50/60
1800*1600
*1600
3200
400
300
500
0.4/0.69
0.8
50/60
2000*2000
*2000
4000
500
375
625
0.4/0.69
0.8
50/60
2300*1800
*1800
5000
600
450
750
0.4/0.69
0.8
50/60
2500*2000
*1800
6000
800
600
1000
0.4/0.69
0.8
50/60
3000*2438
*2000
7000
1000
750
1250
0.4/0.69
0.8
50/60
3000*2438
*2500
8000
1200
900
1500
0.4/0.69
0.8
50/60
3500*2438
*2500
9000
1500
1125
1875
0.4/0.69
0.8
50/60
4000*2438
*2500
10000
1800
1350
2250
0.4/0.69
0.8
50/60
4500*2438
*2500
11000
2000
1500
2500
0.4/0.69
0.8
50/60
5000*2438
*2500
12000
2200
1650
2750
0.4/0.69
0.8
50/60
5500*2438
*2500
13500
2500
1875
3125
0.4/0.69
0.8
50/60
6000*2438
*2500
15000
3000
2250
3750
0.4/0.69
0.8
50/60
6500*2438
*2500
17000
COOLING FAN
The load cooling system is composed of multiple large fans and automatic protection devices, which can quickly disperse the heat converted by the power module and maintain the appropriate
temperature in the load bank.
(1) The load adopts the special low-noise and waterproof axial flow fan at sea, which has high strength, corrosion resistance and durability.
(2) Multiple temperature sensors are installed at the load part and air outlet. When the temperature reaches the warning value, the load can be cut off automatically to ensure that the load will
not be damaged due to excessive temperature.
For the main components of the above load cabinets, we choose internationally advanced and reliable components with many years of experience to ensure the quality of the system.