Conventional Fire Alarm Control Panel Fire Alarm System

FOB Price: Get Latest Price
|
- (Min. Order)
  • Supplying Ability500 Sets Per Month
  • Supplying TypeOem service
  • Model NumberCK1004
  • Preferred Payment Method:T/T, Western Union, Money Gram

shenzhen Anogy technology Co.,ltd

China

Port: shenzhen

Quick Details

  • package:100PCS/CTN
  • Processing Time:10/DAY
  • Port:shenzhen
  • Supply Ability: 500 Sets Per Month
  • Brand Name:ANJ
  The CK1000 is a 4-zone to 16-zone FACP (Fire Alarm Control Panel), which uses conventional input devices.  The panel accepts water flow devices, two-wire smoke detectors, four-wire smoke detectors, pull stations and other normally-open contact devices. Outputs include four Notification Appliance Circuits (NAC, SOUND1-4), three standard Form-A relays (alarm, trouble and supervisory) and an EIA-485 port to interface with remote annunciators and optional remote relay modules. The FACP is field programmable via the panel keypad.  It also supervises all wiring, AC voltage and battery level.   This series of panels are basically the same in application and operation, their differences are shown in Table 1-1. CK1000 will be described as the example in the following sections.   Table 1-1 FACP Number of Detection Zones Number of Sounder Outputs Output Delay Settings CK1004 4 1 N/A CK1008 8 2 N/A CK1016 16 4 N/A   1.1 Product Features   l  4,8,16 Class B Initiating Device Circuits (IDCs) ✓   All zones accept conventional detectors and any normally open contact device l  Four Class B Notification Appliance Circuits (NACs) l  One Form-A Alarm Relay l  One Form-A Trouble Relay l  One Form-A Supervisory Relay l  3.0 amps of system power l  Max 20 conventional detectors in one zone. l  Auto/Manual mode setting enable walk test. l  Each Zone can be disabled, l  Sound output can be disabled. l  Manual active sound output enabled. l  Able to report short and broken circuit of detection zones. l  Designed with standby batteries and space provision for two sealed lead-acid batteries. l  Testing and disable functions.   1.2 Specifications   AC Power AC90-270 VAC, 50 Hz, 2.3 amps Wire size: minimum #14 AWG (2.0 mm2) with 600V insulation Battery (lead acid only) Maximum Charging Circuit: Normal Flat Charge—27.6V @ 0.8 amp Maximum Charger Capacity: 18 Amp Hour batter Sound Output Device Circuits General Alarm Zones 1 through 16 Operation: All zones Class B Normal Operating Voltage: Nominal 24 VDC (ripple = 100 mV maximum) Alarm Current: 15 mA threshold Short Circuit Current: 42 mA maximum Maximum Loop Resistance: 100 ohms End-of-Line Resistor: 4.7K, ½ watt Detector Loop Current is sufficient to ensure operation of two alarmed detectors per zone Standby Current: 7.26 mA Three Relays Output Relay contact rating: 2.0 amps @ 30 VDC (resistive), 2.0 amps @ 30 VAC (resistive) Nonresettable 24 VDC Power Maximum ripple voltage: 10 mVRMS          Operating Voltage nominal 24 volts Total DC current available from this output is up to 500 mA Recommended maximum Standby current is 150 mA