Join today and be a part of the fastest growing B2B Network Join Now

JTY-GD-2412/24E point type photo-electric smoke detector

  • Origin: Thailand
  • Supply Type: oem service
  • Processing Time: 15 - 25 days
  • Min Order: 40

Supplier Info.

  • Employees Total 5-10
  • Annual Revenue
Supply Ability
Supply Ability:100 Piece/Pieces per Week
Packaging & Delivery
Packaging DetailsPacked with carton or wood boxesPortLeam Chabang PortPicture Example:
package-img
Lead Time :
Quantity(Pieces)1 - 1011 - 50>50
Est. Time(days)1525To be negotiated

JTY-GD-2412/24E point type photo-electric smoke detector

Product Description

I. Overview of JTY-GD-2412/24E Point Photoelectric Smoke Smoke Detector

JTY-GD-2412/24E Photoelectric Smoke Detector is a dual-source dual-chamber photo-electric smoke detector using modern modern technology. It can work under the supply voltage of 12V system, especially suitable for security system and detector. After the alarm, a built-in relay can be activated to provide two pairs of normally open and normally closed contacts for interlocking external devices.

The JTY-GD-2412/24E Photoelectric Smoke Detector is designed to provide protection for open areas and must be used with compatible four-wire controllers. The detector's health and sensitivity can be tested in the field.

As a self-locking detector, when the alarm is locked, it must be reset by momentary interruption of the power supply. The JTY-GD-2412/24E photo-electricity smoke detector has a light-emitting diode as the display of the detector. If the detector is energized and in normal monitoring, the LED will flash every 10 seconds. In the alarm state, the LED will lock steady until the detector is reset.

The JTY-GD-2412/24E Photoelectric Smoke Detector contains a pair of normally open contacts (Type A) for connection to the alarm control circuit and a set of normally open/normally closed auxiliary contacts (Type C). Monitoring of the detector power supply is accomplished by installing a power monitoring terminal relay at the end of the detector power circuit. When current is applied to and through the detector, the terminal power monitoring module is powered up and its relay contacts are closed to cause the controller's alarm loop to form a closed series circuit. Once the power is turned off or the detector circuit is disconnected, the terminal module will lose power and the relay contacts will disengage and trigger a fault signal to the controller.

2, JTY-GD-2412/24E point type photo-electricity smoke fire detector technical parameters

14cm (5.5 inches) in diameter

Height 8.1cm (3.19 inches)

Weight 310g (0.7 lbs)

Operating temperature range -10 ° C to 50 ° C (14 ° to 122 ° F)

Operating humidity range 10% to 95% RH relative humidity

Alarm reset instantaneous power off

Maximum wind speed 15M / S (3000 feet / Min)

Relay contact parameters

Resistive or inductive (60% power factor) load

Type A: 2.0A@30VAC/DC

Type C: 0.6A@110VDC, 2.0A@30VDC

1.0A@125VDC, 2.0A@30VDC

Electrical parameters: 12VDC power supply 24VDC power supply

System voltage: 12DC (maximum 4V fluctuation) 24DC (maximum 4V fluctuation)

Supply voltage: 11.3VDC minimum, 17.0VDC maximum 20VDC minimum, 29VDC maximum

Reset voltage: 0.73VDC minimum 0.8VDC minimum

Quiescent current: 120μA maximum 120μA maximum

Alarm current: 35.0mA minimum 77.0 maximum 21.3mA minimum, 40.6mA maximum

Reset time: 0.3 seconds 0.3 seconds

Power-on time: 34 seconds 34 seconds

FOR MORE DETAILS PLEASE CALL OR EMAIL US

CONTACT NUMBER.+66636524055

WHATSAPP. +66636524055

EMAIL.. [email protected]