SNV-EKL3.2 earth fault sensor and short circuit indicator with DIP setting current

  • Origin: China
  • Supply Type: oem service
  • Processing Time: 10-15 working days
  • Min Order: 10

Supplier Info.

  • Employees Total 51-100
  • Annual Revenue

SNV-EKL3.2 Earth fault and short circuit indicatorÂ

Description

 SNV-EKL3.2 Earth fault and short circuit indicator, it Widely used in various ring cabinets, high-voltage switch-gear and cable branch box in power system, can accurately and reliably detect the fault section and fault type of power grid. The use of Earth fault and short circuit indicator is an efficient way to check cable fault, and is an effective way to improve the operation level of distribution network and the efficiency of fault handling. The design uses electromagnetic induction, toelectric conversion, iber transmission and single chip microcomputer control technology to make fault alarm with high accuracy and strong anti-interference ability.

Equipped with fault remote transmission port, suitable for distribution network automation; Â Battery low power alarm indication;Â Low-power design, high-capacity lithium battery power supply, long battery life (more than 8 years); external structure using card or lock design, the whole machine is easy to load and unload.

Function character

Â

1) Intelligent detection of short-circuit and ground fault and through the corresponding LED indicator on the panel to indicate.

2)Display Monitor panel designed with button, it is convenient for reset/or test.

3)It can set The pulse width time(Response time) of fault current for preventing incorrect fault indication caused by surge current.

4)It can set the reset time.

5)It can set the short circuit alarm current via the Dip on short circuit sensor

6)It can set the earth fault alarm current via the Dip on display unit monitor.

7)It can reset and detect the remote fault indication device remotely.

8)It can provide switch volume for external devices through remote relay ;

9)Remote fault indicating can be made by external devices.;

10)Low battery display and alarm

Function description

1) short circuit alarm indicating: when short circuit sensor detected a short circuit fault current, when the current is greater than or equal to the setting value, then the short circuit sensor send alarm r panel through fiber. And the monitor will display the alarm /span>the short circuit fault LED will be flash.

2) Earth fault alarm indicating:  when the earth fault sensor detected a earth fault current, when the current is greater than or equal to the setting value, then the earth fault sensor send alarm r panel through cable. And the monitor will display the alarm time, the earth fault LED will be flash.

3) Battery low voltage alarm indicating: the monitor use the battery to supply power. When the battery voltage is lower than the min. working voltage 2.7V, then the Low voltage alarm led will flash.

4)Automatic reset:  After the indicator alarm the fault, if there are without manual reset it, when the time reach our Reset time setting, indicator will automatically reset.

5) Manual Reset:  After the indicator alarm the fault, user can press the button “ reset/test” to reset it.

6)Remote Reset: During indicator indicating fault, Through the pin 11-12 back of the monitor, connect the remote button to control the indicator reset.

7)Remote Test:  During indicator on normal condition, Through the pin 11-12 of the monitor, connect the remote button to operate simulation test.

8) Remote indicating fault: Connect an External Lamp on the pin 9-10, when the indicator indicating fault, the External blink at same time, then achieved long distance indicating fault.

9) Remote upload SCADA: connecting connect pin13-14, or Pin13-15, when indicator indicating fault, A pload to SCADA.

Â

Technology parameter

Voltage grade

3-40.5KV

Â

Battery life

≥8year

Frequency

50HZ/60HZ

Low voltage alarm of battery

≤2.7V

Short circuit alarm current

 (7 levels)

200/250/300/40A

Short circuit sensor fiber length

4meter, or customized

Earth fault alarm currentÂ

(6 levels)

10/20/30/40/50/60AÂ ,or customized

Earth fault sensor cable length

5 meter,or customized

Reset time

(4 levels)

4H/8H/24/36H

Load fluctuation and escape pulse time setting

Short circuit

40/60/80/160ms

(4 levels)

Rated frequency withstand voltage

2KV/1min

Earth fault

Relay capacity

≤95W

work environment

Temperature

-40℃~+60℃

Alarm current accuracy

±10%

Humidity

≤95%RH

Working power

ER17505

battery

3.6V/3500mAh

Use for cable diameter

Short circuit CT

(Fiber, Type S)

A

Ф20mm~40mm,

Normally

B

Ф300mm~70mm customized

Working current

Standby state

≤10μA

Earth fault sensor

(Cable, type E)

A

Ф60mm~100mm

Normally

Working state

≤1mA

Indicator protection level

Monitor panel

IP 40

B

Ф80mm~130mm

Customized

Sensor CT

IP 67