BET surface area analyzer V-Sorb 2800S

  • Origin: China
  • Location: Beijing
  • Min Order: 1

Quick Details

Testing stations 2
Pretreatment stations 2
Testing data Single and multi-point BET surface area

Supplier Info.

  • Location Beijing
  • Employees Total 51-100
  • Annual Revenue US$50 Million - US$100 Million
V-Sorb 2800S BET surface area analyzer introduction  V-Sorb 2800S BET surface area analyzer is researched and developed by Gold APP Instruments for single and multi-point BET (Brunauer-Emmett-Teller) specific surface area, also with Langmuir surface area and others related with SSA (specific surface area) by using static volumetric principle. Compared with other companies’ analyzers, multi pioneered techs make its performance much better, heighten accuracy and consistence of results, enhance measurement stability, all these lead to a leading level in international competitors. Analyzers designed from the user perspective and equipped with fully automated operation, user-friendly interface makes it easy to learn, imported accessories assure stability and prolong life. Perfect design, sophisticated production and strict testing guarantee to meet customers’ real demands. High cost performance of V-Sorb 2800S BET surface area analyzer easily ensure your investment profits and flexible equipped peripheral can satisfy different users’ requests.   V-Sorb 2800S BET surface area analyzer application  Super micro powder, nanomaterials, nanoparticle and fiber shaped specific surface area analysis. Product quality control for powder materials related corporations. Research institutes, universities for BET (Brunauer-Emmett-Teller) theory teaching. Fuel cells, catalysts, additives, adsorbent, ceramics, magnetic materials, energy storage materials etc. Other researches concern specific surface area performance.   V-Sorb 2800S BET surface area analyzer parameters  Analysis Method: static volumetric nitrogen adsorption principle Versatility: Adsorption and desorption isotherms, Single and multi-point BET (Brunauer-Emmett-Teller)  surface area, Average particle diameter estimation, t-plot external surface area, True density analysis, Langmuir surface area, carbon black (STSA-Statistical thickness surface area), adsorption constant C. Measuring Ranges: 0.01 m2/g (by nitrogen)/ 0.0005m2/g (by krypton) to no known upper limit Accuracy: repeatability errors ≤1% Vacuum System: V-Sorb unique monolithic manifolds and solenoid valve control system, greatly reduce the dead volume; improve the adsorbate micro-change sensitivity; enhance pore size distribution analysis resolution; decrease connecting points; strengthen sealing performance and prolonged instrument life Coolant Level Prober: V-Sorb original coolant level control system with temperature probe, ensure the coolant level unchanged when compares with sample cells in the whole analysis process, completely eliminate the analysis errors caused by dead volume change Sample Treatment: the whole treatment procedures are controlled by dedicated software, as well with a start time preset function which can realize unattended operation at night Control System: programmable solenoid valve system with high integration and strong anti-interference ability, enhance instrument stability and life Sample Ports: two samples analyzing and two samples degassing concurrently Pressure Measurement: imported sectional measuring dual pressure transducer, notably improve the measuring accuracy at low P/Po point, 0-1000Torr (0-133Kpa), 0-10Torr (0-1.33Kpa) Transducer Accuracy: imported silicon thin film pressure transducer, accuracy can reach 0.1% of real reading, better than 0.1% of F.S.(full-scale), far accurate than Pirani resistance vacuum gauge(general error is 10%-15%) Partial Pressure: P/Po controllable accuracy range is 5x10-6-0.998 Ultimate Vacuum: 4x10-2Pa (3x10-4 Torr) Vacuum Pump: built-in bipolar vacuum pump controlled by patented software which can auto control pump’s start/stop Sample Types: powders, nanoparticle, fiber, flakes and other materials Adsorbate Gas: high purity nitrogen (≥99.999%), Ar, Kr, CO, CO2, C4H10 etc. non-corrosive gases are optional Data Acquisition: high-precision and high integration data acquisition modules, minimal error, strong anti-interference ability Data Reduction: Windows®-based independent developed Gold APP Instruments softwareTM, perfect versatility, produced full featured and multi-model reports   V-Sorb 2800S BET surface area analyzer features  A: Vacuum System Unique integral manifolds system, decrease connecting points apparently, reduce leak rate, improve ultimate vacuum. Modularity design can configure as customer requests, benefits future functions extension and instrument maintenance. Germany imported bipolar vacuum pump, low noise, stable working, oil-return prevention; ultimate vacuum can reach 4x10-2Pa (3x10-4Torr).  B: Control System Industry used programmable solenoid valve system, strong anti-interference ability, convenient for installation and uninstallation. Separated analysis and treatment manifolds can prevent foreign matter to contaminate manifolds in sample treatment.  C. Measures for Improving Accuracy Imported silicon thin film capacitive pressure transducer, accuracy can reach 0.1% of real reading, better than 0.1% of F.S. (full-scale). 0-10Torr (optional) and 0-1000Torr dual pressure transducers, sectional measurement in pressure range can reduce errors in low vacuum, 0-10Torr silicon thin film transducer is highly accurate than Pirani resistance vacuum gauge (general error is 10%-15%). Unique monolithic manifolds system, decrease connecting points and reduce leak rate apparently. Original stepping coolant level control system, ensure the coolant level unchanged when compares with sample cells in the whole analysis process, completely eliminate the analysis errors caused by dead volume change. Pioneered gas outlet and inlet control system can efficiently prevent sample splash in evacuation and gas inlet process, guarantee clean manifolds and sample weight unchanged, avoid zero and liner drifting caused by transducer’s macro-change.  D. Data Acquisition and Reduction High precision and integration data acquisition module is easy to connect, minimal errors and strong anti-interference ability; standard 485 communication mode is good for analyzer’s applications extension and interconnection, can also conveniently switched to RS232 and USB modes. Multi calculating methods for data reduction provides all-round sample analysis options; powerful data archiving and searching system helps a lot for data management.    Our policy of continuous development may cause the information and specifications contained herein to change without notice or liability.
Premium Services
Need Buyers
Girl Right
Cross Popup
Arrow 2

I Am :

Signup today to claim your Discount. Get Started before it's too late!

Arrow 1
We use cookies to ensure that we give you the best experience on our website. If you continue to use this site we will assume that you are happy with it. Ok