Addressable heat detector/alarm addressable fire alarm control system

  • Origin: China
  • Supply Type: oem service
  • Processing Time: 10/DAY

Quick Details

Package 100PCS/CTN

Supplier Info.

  • Employees Total 11-50
  • Annual Revenue US$10 Million - US$50 Million
I. Product overview JTY-GD--920E addressable heat detector (Detector hereunder) is a mated product of the 9000 series fire alarm control panels. It uses a two-bus work mode. With an internal microprocessor, it supports electronic coding. The detector realizes real-time acquisition of the in situ temperature data and sends back the data to a fire alarm control panel. It can also receive and execute the control commands given by a fire alarm control panel. When in a routing inspection, the detector indicator will blink. When there is a fire in the monitored area and the temperature has reached the alarm threshold, the fire alarm control panel will confirm a fire alarm according to the received message sent from the detector, and the detector indicator will light at the same time to indicate a fire alarm. The detector is suitable for such industrial and civil buildings that have a great deal of heat when fire takes place, such as kitchens, boiler rooms, generator rooms, drying workshops and smoking rooms and is not suitable for places with a great deal of smoke but little heat. II. Product features ü It can realize electronic coding and rewrite the address via coder in situ. ü Within a single-chip microcomputer, it can realize real-time data acquisition and processing, realize a curve tracing for the field situation. ü It has a temperature compensation function and a sensor fault detection function (fault reporting to fire alarm control panel). ü Non-polarity, two-bus connection that ensures convenient installation and maintenance. ü Designed with an upper cover and a lower cover and installed on an independent base, it can be installed, debugged and maintained conveniently. III. Technical parameters 1. Executive standard: GB4716-2005 2. Operating voltage: 24V (pulse modulation) 3. Operating current: <300uA (monitoring status) or <1.5mA (alarm status) 4. Work indication: The red indicator will blink in the monitoring status or remain lit in the alarm status. 5. Weight: about 47g 6. Product class: A2 7. External dimensions: diameter: 100mm, height: 56mm (with the base) 8. Wiring method: non-polarity two-bus system (L1, L2) 9. Operating environment: Indoor, temperature: -10℃~+50℃; relative humidity: ≤95% (40℃±2℃, without condensation) 10. Coding mode: It can realize electronic coding via coder in situ. Address codes 1 to 324 are available for selection. 11. Installation height: ≤8m 12. Protection area: about 60m2. For details, see related provisions in GB50116-98 Code for Design of Automatic Fire Alarm System. 13. Matched host machine: fire alarm control panel (such as CFT-MN3010) Specific installation and debugging methods: 1. Make sure the type of the detector matches the type of the host machine of the fire alarm control panel; 2. Use two M4 screws to fix the matched mounting base on the designated position via the mounting holes C and D shown in Fig.5, as instructed in the construction drawing and make sure the matched mounting base has been firmly installed. 3. Use a coder to make the detector coded according to the detector address on the construction drawing. 4. Disconnect the power supply of the fire alarm control panel and connect the detector correctly according to the construction drawing. 5. Place the indicator at position A of the detector (see Fig.1) and position B of the base (see Fig.5), align them with each other, insert the detector into the base and turn the detector clockwise until it is firmly locked. 6. After all the products are installed and checked, connect the power supply of the fire alarm control panel and conduct automatic login. 7. when automatic login is success, the red indicator of the detector will blink once about every 12 seconds, which suggests that the detector has begun to operate normally. 8. Finally conduct an alarm test for the detector through some special tools or direct hot air gun blowing. After the detector gives a fire alarm, the indicator will remain lit and the fire alarm control panel will simultaneously give corresponding alarm prompt information. After the alarm test, reset the fire alarm control panel and restore to the monitoring status.
Premium Services
Tell us what you need
Girl Right
Cross Popup
Arrow 2

I Am :

Signup today to claim your Discount. Get Started before it's too late!

Arrow 1
We use cookies to ensure that we give you the best experience on our website. If you continue to use this site we will assume that you are happy with it. Ok