Specifications
Basic Information | Measurement method | Electrochemical Biosensor Technology | ||
Enzyme type | GDH-FAD | |||
Intended Use | Home testing or professional use to monitor the blood glucose (β-D-glucose) levels in fresh capillary whole blood from fingertip and venous whole blood. Venous blood tests can only be measured by professionals. | |||
Measuring Principle | Using the latest biosensor technology. It measures the glucose levels of the blood specimen by using a disposable dry reagent strip which can produce an electrical current. And the current will transfer to the meter for measurement. The amount of the current is proportional to the amount of glucose present in the blood sample. Test results are âplasma equivalentâ. | |||
Display mode | Reflective TN LCD | |||
Key quantities & functions | 3 keys (Mode, forward, backward) | |||
Battery | 2*CR2032 | |||
Operating environment | Temperature: 10âï½40â (50â~104â); Control solution: 20âï½30â | |||
Humidity: 80% R.H. | ||||
Storage/ Transport environment | Meter: Temperature: -40âï½55â / Humidity: 90% R.H. | |||
Strip: Temperature: 4âï½30â / Humidity: 90% R.H. | ||||
Control: Temperature: 2âï½30â / Humidity: 90% R.H. | ||||
Product Life | Meter: 5 years | |||
Strip: Shelf life: 24 months; Shelf life after opening: 180 days (Below 30â) | ||||
Control: Shelf life: 24 months; Shelf life after opening: 90 days (Below 30â) | ||||
Measurement range of glucose | 10ï½600 mg/dl ( 0.5ï½33.3 mmol/l) | |||
Control solution concentration range | Medium level: 120~164 mg/dl (6.6~9.2 mmol/l) | |||
High level: 362~492 mg/dl (20.1~27.4 mmol/l) | ||||
Accuracy range of measurement | If glucose concentration < 100 mg/dl, Bias % (95% CI) ±15 mg/dl | |||
else Bias % (95% CI) ±15% Ref. YSI 2300 | ||||
System accuracy (ISO 15197) | Criterion A | 95% of measured value fall within either ±15 (<100mg/dl) mg/dl or 15% (100 mg/dl) of reference | ||
Criterion B | 99% of measured value within CEG zones A and B | |||
Hematocrit Range | 0%~70% | |||
Measuring time | 5 seconds | |||
Sample volume | 1.0 µl | |||
Control solution volume | 4 ml | |||
Function | Unit Display | mg/dl and mmol/l | ||
Time display | 12h | |||
Memory mode (Sets) | 1000 | |||
Average display | Last 7 / 14 / 30 / 60 / 90 Days averaging | |||
Talking function | No | |||
Ketone warning / Voice indicator (Beep) | No | |||
Insufficient sample volume detection | Yes | |||
Meal Comment | Yes, Pre/Post Meal Marker | |||
Before / After meals Average of blood glucose | No | |||
Data-Link | AM100 PD-B: Yes (Including sion and mission) | |||
AM100 PD: Yes (Including sion) | ||||
Package | Test Strip | vial | 25 pcs/vial | |
50 pcs/vial | ||||
box | 1 vial/ box, including instruction | |||
2 vials/box, including instruction | ||||
Meter | box | Including 1 meter, 1 userâs guide, 1 Logbook, 1 Lancing device, 50 Lancets | ||
Control Solution | Pouch | Including 1 control solution medium level, 1 control solution high level, control solution instruction (Packed in the blood glucose meter pouch) |